730 Bubbler ModuleInstallation and Operation GuidePart #60-9003-063Copyright © 1995. All rights reserved, Teledyne Isco, Inc.Revision K, May 9, 2007
730 Bubbler ModuleSection 1 Introduction1-21.2 Connecting to the SamplerTo install the module:1. Turn the sampler off.2. Remove the connector cap in
730 Bubbler ModuleSection 1 Introduction1-31.6 General Mounting Considerations for the BubblerThis section contains some general information regardin
730 Bubbler ModuleSection 1 Introduction1-41.6.4 Bubble Line ExtensionsFor some applications, a stainless steel tube may be easier toinstall in the f
2-1730 Bubbler ModuleSection 2 Programming the Module2.1 Module Screens When the controller is configured with the module, it adds thenecessary screen
730 Bubbler ModuleSection 2 Programming the Module2-2Figure 2-1 Sample ReportsSAMPLER ID# 11343009 15:25 13-SEP-03 *********** PROGRAM SETTINGS *
730 Bubbler ModuleSection 2 Programming the Module2-3Figure 2-2 Sampler Programming: 730 Module ScreensSELECT UNITS FORFLOW VOLUME:cf gal Mgalm3
730 Bubbler ModuleSection 2 Programming the Module2-4Figure 2-3 Sampler Programming: 730 Module Setup ScreensMODE OF OPERATION: FLOWMETER LEVEL ONLY
730 Bubbler ModuleSection 2 Programming the Module2-5Figure 2-4 Sampler Programming: 730 Module Quick View ScreensSITE DESCRIPTION:"FACTORY"
730 Bubbler ModuleSection 2 Programming the Module2-62.4 Operation of the Bubbler SystemWhen measuring flow rate, the module is used with a primaryme
730 Bubbler ModuleSection 2 Programming the Module2-7The following table contains programming information for eachof the conversion types.2.5 Alterna
730 Bubbler ModuleSection 2 Programming the Module2-8
3-1730 Bubbler ModuleSection 3 Installation MethodsThe bubble line may be installed in many different channeltypes, which are summarized here. For mor
730 Bubbler ModuleSection 3 Installation Methods3-2You may exit the programming after setting the currentlevel to zero. When you install the flow met
730 Bubbler ModuleSection 3 Installation Methods3-3Route the vinyl bubble line away from the carrier and along thespring ring’s edge with holes. Secu
730 Bubbler ModuleSection 3 Installation Methods3-4diameter. The 9.0" (the smallest) extension exists so that inlarger pipe sizes, where large v
730 Bubbler ModuleSection 3 Installation Methods3-5Figure 3-3 Bubbler Carrier Mounted on Scissors Ring3.1.4 Street Level Installation SystemThe Stree
730 Bubbler ModuleSection 3 Installation Methods3-6Figure 3-4 Typical installation methodsWeirSensorMounting Plate Round PipeSpring Ring Parshall Flu
4-1730 Bubbler ModuleSection 4 MaintenanceThe 730 Bubbler Module has no user serviceable parts. It is com-pletely sealed to protect the internal compo
730 Bubbler ModuleSection 4 Maintenance4-2The filters in the end caps keep small pieces of the desiccantmaterial from falling out of the cartridge. W
A-1730 Bubbler ModuleAppendix A Accessories ListThe following table contains information about replacementparts and accessories. Replacement parts an
ForewordThis instruction manual is designed to help you gain a thorough understanding of theoperation of the equipment. Teledyne Isco recommends that
730 Bubbler ModuleAppendix A Accessories ListA-2Pair of 30” Extensions for Scissors Ring 68-3000-040Pair of 40” Extensions for Scissors Ring 68-3000-
B-1730 Bubbler ModuleAppendix B Technical SpecificationsThe following table contains information covering the technicalspecifications of the 730 Modu
730 Bubbler ModuleAppendix B Technical SpecificationsB-2
C-1730 Bubbler ModuleAppendix C Material Safety Data SheetsThis appendix provides Material Safety Data Sheets for the des-iccant used by the 730 Bubb
730 Bubbler ModuleAppendix C Material Safety Data SheetsC-2*Optional Indicating Silica GelMaterial Safety Data Sheet Indicating Silica GelIdentity (T
730 Bubbler ModuleAppendix C Material Safety Data SheetsC-3*Optional Indicating Silica GelPage 2Section 5 - Health Hazard DataPRIMARY ROUTES I
730 Bubbler ModuleAppendix C Material Safety Data SheetsC-4 MATERIAL SAFETY DATA SHEETEffective Date March 8, 2005 MSDS Number M163Secti
730 Bubbler ModuleAppendix C Material Safety Data SheetsC-5Section 4 – First Aid MeasuresEyes:Rinse the eyes well with water while lifting the eye li
730 Bubbler ModuleAppendix C Material Safety Data SheetsC-6Section 8 – Exposure Controls/Personal ProtectionEngineering Controls: Use exhaust ventila
730 Bubbler ModuleAppendix C Material Safety Data SheetsC-7Section 11 – Toxicological Information This product and its components are not listed on t
730 Bubbler ModuleAppendix C Material Safety Data SheetsC-8Section 16 – Other Information HMIS – Hazardous Materials Identification System HMIS Ratin
Compliance StatementsCE Declaration of ConformityDECLARATION OF CONFORMITY Application of Council Directive: 89/336/EEC – The EMC Directive 73/23/
War ran tyTeledyne Isco One Year Limited Factory Service Warranty * Teledyne Isco warrants covered products against failure due to faulty parts or wo
730 BubblerModuleSafetyiii730 BubblerModuleSafet yGeneral Warnings Before installing, operating, or maintaining this equipment, it isimperative that a
730 BubblerModuleSafetyivDANGERDANGER – limited to the most extreme situations to identify an imminent hazard, which if not avoided, will result in de
v730 Bubbler ModuleTable of ContentsSection 1 Introduction1.1 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
730 Bubbler ModuleTable of ContentsviAppendix B Technical SpecificationsAppendix C Material Safety Data SheetsList of Figures1-1 730 Module Mounted on
1-1730 Bubbler ModuleSection 1 Introduction1.1 Introduction The 730 Bubbler Module is one of Teledyne Isco’s inter-changeable modules for the Avalanch
Commentaires sur ces manuels